![]() ![]() Selecting an "acd" file from the Demonstrations page of the PanelBuilder32 CD documentation loads the "acd" file into Notepad instead of RSLogix5000. To open the file with RSLogix5000, right-click on the "acd" file and select "Save Target As." in order to save the file to your hard drive where it can be opened with RSLogix5000. RSLinx version 2.54.00 is included on this PanelBuilder32 CD. If you have an older version of RSLinx (older than version 2.54.00), it is recommended that you upgrade your system to RSLinx, version 2.54.00 via the PanelBuilder32 main install menu or via a 'Typical PanelBuilder32 Install'.ĭisplay of RSLinx online help information requires MS Internet Explorer v3.02 or later to be installed. ![]() The latest version of MS Internet Explorer can be obtained from Microsoft's web site. On Windows NT systems, RSLinx may require administrator rights to successfully install the program.įor further software and hardware requirements pertaining to the RSLinx installation check the "Getting Results with RSLinx" manual, results.pdf, in the \PB32\RSLinx\Redist\OnlineDoc\ENU directory of the PanelBuilder32 CD. If you found this content helpful, consider buying me a coffee here.If installing PanelBuilder32 on a computer with the KFD Driver configured and in a stopped state, you may need to disable your KFD driver or reconnect the DeviceNet cable before downloading a PanelView Application after a computer reboot. Have a question? Join my community of automation professionals and take part in the discussion! You'll also find my PLC, HMI, and SCADA courses at. questions, suggestions, or corrections please don’t hesitate to share them by using the “post a comment or question” link below. I hope the above step-by-step procedure on how to import legacy PanelView projects into FactoryTalk ViewStudio was helpful. Migrating PanelView Enhanced Applications.Migrating PanelView Standard Applications.Note: For more information about migrating old PanelView projects to FactoryTalk View check out the below migration guides: Step 9) Now you have completed the importing of your legacy PanelView project into FactoryTalk ViewStudio: All errors in this log will need to be considered before deploying your imported code: Step 8) Once the import finishes, you will be prompted with a popup displaying the conversion results. Step 7) Select your import options and then press “Finish:” Note: In this example we will import a PanelView 1000 RIO Demo Project: Step 6) Browse for your legacy PanelView file, select it, and press “Next:” Note: PanelBuilder Enhanced and pre-6.1 PanelView Plus projects can not be imported on Windows 7 64 bit without first preforming a lagecy tag database export on a 32bit OS. Note: PanelBuilder 1200 projects must first be imported to PanelBuilder 1400e (enhanced) software and saved as a “.PVC” Step 5) Select the type of legacy PanelView project you would like to import and press next: Step 4) Press “OK” after reading the notice: Step 3) Next, click on the “Import” button ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |